Exsenco U.S Contact For Santest

GYAF

 

Photograph 3
The GYAF probe is all in one type sensor which builds in the controller. Direct current 24V just is supplied can obtain analog voltage or the electric current which is proportionate to the magnet. It is correspondence possible even in reversal output and bipolar output. The thin-shaped head made the miniaturization of the device possible, flange installation improved operating efficiency in comparison with former screw system.
3
3
 

Specifications

3
Precision Linearity Below TYP ±0.025%FS
Resolution Below 0.01%FS
Repeatability Below ±0.01%FS
Temperature characteristic Below 40ppm FS/℃
Output Voltage output 0 - 10V or 10 - 0V
Load resistance Min 2kΩ
Electric current output 4 - 20mA or 20 - 4mA
Load resistance Max 500Ω
Frequency characteristic Scanning frequency 1kHz (standard)
Power source and electric power consumption DC24V±2V 0.1A (at the time of scanning frequency 1kHz)
Environmental characteristic Resisting pressure 35MPa (static pressure)
Category temperature range -20℃ - +80℃ (Note 1)
Storage temperature range -40℃ - +80℃
Resistance swing shock resistant 6G (or 40Hz 2mmPP) 50G (2msec)
Protective standard IP67 (Note 2)
* The above-mentioned precision is applied when it is above effective stroke 300mm.
Note 1) 0 temperature range of the category temperature range has supposed the use at cold area. When only the probe rod low it becomes temperature, separate consultation.
Note 2) Protective standard IP67 withstands the use 30 minutes to the depth of water 1m. (You cannot use for the use which it submerges continually) 3

Type Variations

3
3
 
GYAF1-□□□□-□□-□□
1 Effective stroke
3 300, 500, 700, 1000, 1500 and 2000 (max3000mm)
2 Output
3 A: 0 - 10V B: 4 - 20mA C: In addition
2 Operational direction (to rod point when moving)
3 D: Increase operation R: Decrease operation
2 Cable removal
3 CN: Connector type G*: [piguteiru] type (standard) (* cable length (m): Standard 1.5m)
 
CLAF-□□-□
1 Cable length (m)
3
2 Cable type
3 S: Standard cable W: Submerging cable
3
3

External Dimensions Drawing

3
3 - [piguteiru] type
3
3 Material rod: SUS304
   Head: SUS304 Bs (nickeling)
Protective standard IP67
Cable function table
3
Cable color

Function

Yellow DC24V
White 0V
Blue Output
Green SIG COM
* At user side you connect the seal to 0V.
*0V and SIG COM are connected in inside.
[piguteiru] type
3 - Connector type
3
3 Material rod: SUS304
   Head: SUS304 Bs (nickeling)
Connector TC1108-12A10-7AF (Tajimi radio electrical machinery and appliances make)
Protective standard IP67 (option IP68)
Connector connected chart
3
Pin numbering

Cable color (S)

Cable color (W) Function
A Yellow Red +24V
B Seal Seal Seal
C White White 0V
D Green Green SIG COM
E (Blue) Black Voltage output
F (Blue) Blue Electric current output
G     Non function
* At user side you connect the seal to 0V.
*0V and SIG COM are connected in inside.
Connector type
3 3 3 3 3
3

Options

3
With option it can produce the effective stroke of the probe at optional length.
Adaptation O the ring is P-14. Please be sure to jointly use the backup ring.
Cable length voltage output type 10m and electric current output type 100m use in standard.
Complete submerging connector type (IP68) you can select. At that time the depth of water 30m (300kPa) continuing to under the water pressure, sinking in underwater, you can use. In addition, submerging efficiency is shown in fit state of the connector.
Also voltage and electric current simultaneous output type are production possible with option.