GYcAT
All-in-One, Low Cost Thanks to the Surface Mount Technology, the entire signal processing electronics of GYcAT series is integrated into a transducer head. You can get a voltage or current analog signal proportional to a magnet position only by applying a 24V dc power supply directly to the transducer. GYcAT series have alarm output and head is equipped with noise cancellation functions. Model Selection
|
Dimensions
Material probe head:Al diecast, probe rod: SS304
Standard magnet:No.2P. Other magnets are available from Magnet Grouping [B].
The tip dead zone length (70mm) depends on the magnet or float type.
The length of the cable should be less than 10m in case of using the voltage output type
and 100m in case of using the current output type.
Connector: Sanwa SNW-1607-PCF (Material: zinc alloy fluoroplastic)
Applied cable diameter:Φ6.6-Φ7.5
Wire size:Less than 0.5mm2
Connection
1 DC24V
2 NC
3 0V
4 SIG COM
5 Voltage output
6 (Current output)
7 Alarm output
*Shield should be connected with 0V at user side.
Standard magnet:No.2P. Other magnets are available from Magnet Grouping [B].
The tip dead zone length (70mm) depends on the magnet or float type.
The length of the cable should be less than 10m in case of using the voltage output type
and 100m in case of using the current output type.
Connector: Sanwa SNW-1607-PCF (Material: zinc alloy fluoroplastic)
Applied cable diameter:Φ6.6-Φ7.5
Wire size:Less than 0.5mm2
Connection
1 DC24V
2 NC
3 0V
4 SIG COM
5 Voltage output
6 (Current output)
7 Alarm output
*Shield should be connected with 0V at user side.